Paradyne 3160 User Manual

Page 227

Advertising
background image

SNMP MIB Objects

E-15

3160-A2-GB21-80

March 1999

Near End Group – “dsx1TimeElapsed” Object (dsx1ConfigEntry 3)

Applies to the network interface only. An error status is returned if access is
attempted for the DTE Drop/Insert (DSX-1) interface.

Near End Group – “dsx1ValidIntervals” Object (dsx1ConfigEntry 4)

Applies to the network interface only. An error status is returned if access is
attempted for the DTE Drop/Insert (DSX-1) interface.

Near End Group – “dsx1LineType” Object (dsx1ConfigEntry 5)

This object corresponds to the NET Framing/DTE Framing configuration options
for the T1 interfaces on the DSU/CSU. Only the following values are supported by
the DSU/CSU.

H

dsx1ESF(2) – Indicates ESF framing.

H

dsx1D4(2) – Indicates D4 framing.

Near End Group – “dsx1LineCoding” Object (dsx1ConfigEntry 6)

This object corresponds to the NET Coding/DTE Coding configuration options for
the T1 interfaces on the DSU/CSU. Only the following values are supported by
the DSU/CSU.

H

dsx1B8ZS(2) – Indicates B8ZS line coding.

H

dsx1AMI(5) – Indicates AMI line coding.

Near End Group – “dsx1SendCode” Object (dsx1ConfigEntry 7)

This object specifies the test patterns/codes being sent over the network
interface. These tests are not supported on the DTE Drop/Insert (DSX-1)
interface. Only the following values are supported by the DSU/CSU.

H

dsx1SendNoCode(1) – Specifies that the interface is sending normal or
looped data. Setting the interface to this value stops an active “send pattern”
test on the interface. This is the only value supported by the DTE Drop/Insert
(DSX-1) interface.

H

dsx1SendLineCode(2) – Specifies that the network interface is sending a
Remote Loopback (Rlpbk) LLBUP code. The code is sent for 10 seconds.

H

dsx1SendResetCode(4) – Specifies that the network interface is sending
Remote Loopback (Rlpbk) LLBDN code. The code is sent for 10 seconds.

H

dsx1SendQRS(5) – Specifies that the network interface is sending a QRSS
test pattern. The pattern is sent until the test is halted (i.e., setting to
dsx1SendNoCode).

H

dsx1SendOtherTestPattern(8) – Specifies that the network interface is
sending a 1-in-8 test pattern. The pattern is sent until the test is halted (i.e.,
setting to dsx1SendNoCode).

Advertising
This manual is related to the following products: