SNMP MIB Objects

E-26

3160-A2-GB21-80

March 1999

Where these object identifiers are defined as follows:

H

testLoopDTLB – OBJECT IDENTIFIER ::= [wellKnownTests 2]

H

testMonQRSS – OBJECT IDENTIFIER ::= [wellKnownTests 3]

H

testMon511 – OBJECT IDENTIFIER ::= [wellKnownTests 4]

H

testSendQRSS – OBJECT IDENTIFIER ::= [wellKnownTests 5]

H

testSend511 – OBJECT IDENTIFIER ::= [wellKnownTests 6]

H

testSendV54Up – OBJECT IDENTIFIER ::= [wellKnownTests 7]

H

testSendV54Down – OBJECT IDENTIFIER ::= [wellKnownTests 8]

H

testSendFT1Up – OBJECT IDENTIFIER ::= [wellKnownTests 9]

H

testSendFT1Down – OBJECT IDENTIFIER ::= [wellKnownTests 10]

Generic Interface Test Table – “ifExtnsTestResult” Object
(ifExtnsTestEntry 5)

This object contains the result of the most recently requested test. Only the
following values are supported by the DSU/CSU.

H

none(1) – No test currently active.

H

inProgress(3) – A test is currently in progress.

H

notSupported(4) – The requested test is not supported.

H

unAbleToRun(5) – The requested test cannot run due to the state of the unit.

Generic Interface Test Table – “ifExtnsTestCode” Object
(ifExtnsTestEntry 6)

This object contains a code that contains more specific information on the test
result. This object is defined as an object identifier. Only the following values are
supported by the DSU/CSU.

H

none – No further information is available. Used for the send pattern/code
and loopback tests.

H

inSyncNoBitErrors – A monitor pattern (QRSS or 511) test has synchronized
on the pattern and has not detected any bit errors.

H

inSyncWithBitErrors – A monitor pattern (QRSS or 511) test has
synchronized on the pattern and has detected bit errors.

H

notInSync – A monitor pattern (QRSS or 511) test has not synchronized on
the requested pattern.