Displaying unit identity – Paradyne 3160 User Manual

Page 43

Advertising
background image

Operation

3-9

3160-A2-GB21-80

March 1999

Table 3-4.

Data Port LEDs (2 of 2)

Name

Meaning

Color

RXD

Yellow

Monitors activity on interchange circuit BB (CCITT 104) –
Received Data. This is data sent to the synchronous data DTE
from the data port on the DSU/CSU.

ON :

Ones are being sent to the synchronous data DTE.

OFF :

Zeros are being sent to the synchronous data DTE.

CYCLING: Both ones and zeros are being sent to the

synchronous data DTE.

CTS

Yellow

Monitors the state of interchange circuit CB (CCITT 106) –
Clear-to-Send sent to the synchronous data DTE.

ON :

CTS is being asserted by the DSU/CSU.

OFF :

CTS is not being asserted.

RTS

Yellow

Monitors the state of interchange circuit CA (CCITT 105) –
Request-to-Send received from the synchronous data DTE.

ON :

RTS is being asserted by the synchronous data DTE.

OFF :

RTS is not being asserted.

NOTE:

The following procedures are examples only. Screen displays may vary
depending on the model of the DSU/CSU.

Displaying Unit Identity

The identity of the DSU/CSU (serial number, model number, software revision
level, hardware revision level, and customer identification) is available through
the Status branch of the front panel menu (see Appendix A,

Front Panel Menu

).

The customer identification is the only identity number you can change.

"

Procedure

To display the DSU/CSU’s identity (ID):

1. From the top-level menu screen, select Stat.

F1

DSU ESF
Stat

Test

Cnfig

F2

F3

2. From the Status screen, press the

key until the ID selection appears on

the screen.