Aborting test patterns – Paradyne 3160 User Manual

Page 136

Advertising
background image

Maintenance

4-34

3160-A2-GB21-80

March 1999

Aborting Test Patterns

Use the Abort command to stop all test patterns or any selected test pattern
active on the DSU/CSU.

"

Procedure

To abort test patterns:

1. From the top-level menu screen, select Test.

2. From the Test screen, select Ptrns.

F1

Test:
Rlpbk Lpbk

Ptrns

F2

F3

3. From the Patterns screen, select Abort.

F1

Patterns:
Abort

Send

Mon

F2

F3

4. From the Patterns Abort screen, press the desired Function key to abort

either All active test patterns, active Send test patterns, or the active Monitor
(Mon) test pattern.

F1

Patterns: Abort
All

Send

Mon

F2

F3

If you select All, the DSU/CSU terminates all active test patterns and displays
the message

Command Complete

. Skip Step 5.

NOTE:

If you mistakenly choose to abort a test pattern that is not currently
running, a

Command Complete

message still displays and the test

pattern currently active still runs. Use the TStat branch to view the test
status to determine if the abort was successful.