Monitoring test patterns – Paradyne 3160 User Manual

Page 135

Advertising
background image

Maintenance

4-33

3160-A2-GB21-80

March 1999

Monitoring Test Patterns

Use the Monitor command to monitor a QRSS test pattern over all the channels
on the network interface, or to monitor QRSS or 511 test patterns on the channels
allocated to an individual port.

This command provides the number of errors detected in the test pattern (5
digits, maximum 99999).

"

Procedure

To monitor a QRSS or 511 test pattern:

1. From the top-level menu screen, select Test.

2. From the Test screen, select Ptrns.

F1

Test:
Rlpbk Lpbk

Ptrns

F2

F3

3. From the Patterns screen, select Mon.

F1

Patterns:
Abort

Send

Mon

F2

F3

4. From the Patterns Mon screen, press F1 for QRSS or F2 for 511.

F1

Patterns: Mon
QRSS 511

F2

F3

5. From the Monitor screen, press the Function key that corresponds to network

or the port for which you want to send a test pattern. Use the scroll keys, if
necessary. (NET does not appear for the 511 pattern.)

F1

Monitor:

Name

NET

Prt1

Prt2

F2

F3

The Monitor screen appears with the error count. If the maximum of 99999 is
exceeded,

OvrFlw

appears instead of the count. If the receiver loses

synchronization while the monitor is active,

No Sync

appears.