Configuring the dsu/csu for snmp or telnet access – Paradyne 3160 User Manual

Page 53

Advertising
background image

Operation

3-19

3160-A2-GB21-80

March 1999

"

Procedure

To copy the configuration options to one or all ports:

1. From the Port Select screen, select Copy.

F1

Port Select:
Copy

Prt1

Prt2

F2

F3

2. Select the port

from which you want to copy the configuration options using

the corresponding Function key.

F1

Copy From:
Prt1

Prt2

Prt3

F2

F3

3. Select the port

to which you want to copy the configuration options using the

corresponding Function key. Or, press F1 (All) to choose to copy to all ports.

F1

Copy To:
All

Prt1

Prt2

F2

F3

Configuring the DSU/CSU for SNMP or Telnet
Access

To configure the DSU/CSU for SNMP or Telnet access:

H

Enable the SNMP agent or Telnet server within the DSU/CSU (see
Appendix C,

Configuration Options

).

H

Select and configure the port that provides the link to the SNMP or Telnet
system.

H

Set the Internet Protocol (IP) address and subnet mask needed to access the
DSU/CSU (see Appendix F,

IP Network Addressing Scenarios

).

H

Select the link layer protocol (PPP or SLIP) for the port that provides the link
to the SNMP or Telnet system.

H

For SNMP links, specify the two community names (and their access levels)
that are allowed to access the device’s Management Information Base (MIB).

Advertising