6. Press F1 (Next) until the Com Port configuration option appears.

7. Select Enab to enable the COM port for the carrier-mounted DSU/CSU.

F1

Com Port:
Next

Enab

Disab

F2

F3

The carrier COM port provides the following functionality:

H

If configured for ASCII, only one ASCII device may be used for the carrier. (If
two COM ports are configured for ASCII, neither will work.)

H

If configured for Mgmt, each device in the carrier can support an Mgmt COM
port; however, each Mgmt COM port must be connected to a different subnet.
To facilitate IP data routing, the device with the closest link to the SNMP
manager or Telnet client should be configured as the IP Bus Master.

H

If configured for either ASCII or Mgmt, the carrier COM port may be
configured to control an external device (e.g., modem, x.25 PAD) through the
use of AT or user-specified commands.

The set of valid characters for control of the carrier external COM port device is
as follows:

H

The numbers: 0 –9

H

The lowercase letters: a–z

H

The uppercase letters: A–Z

H

The space (“ ”) character

H

The ASCII symbols (in ascending order, based on the ASCII code)

H

The End Of Line (EOL) symbol:

H

The caret (‘‘^”) control character is used to select non-printable ASCII
characters. The caret ‘‘^” must be followed by one character which together
form the control sequence.

Table 3-7

defines all of the available control

sequences.