Local Loopback Tests

The Local Loopback tests enable you to conduct circuit testing and fault isolation
for the digital line. The supported local loopback tests are:

H

Line Loopback (LLB)

H

Payload Loopback (PLB)

H

DTE Loopback (DLB)

H

Repeater Loopback (RLB)

H

Data Channel Loopback (DCLB)

H

Data Terminal Loopback (DTLB)

NOTE:

DLB does not appear when the DTE Drop/Insert (DSX-1) interface is
disabled.

The Line Loopback command can be activated and deactivated in response to
commands received over the network interface. The Network Interface
configuration option NET LLB controls whether the DSU/CSU responds to the
commands transmitted on the network interface to initiate LLBs (see Appendix C,

Configuration Options

).

The data port configuration option NET DCLB controls whether the DSU/CSU
responds to inband V.54 commands to initiate DCLB for that port (see
Appendix C,

Configuration Options

).

Local loopback tests can be aborted (Abort Command) at any time.

No more than two local loopbacks can be active at any one time. An additional
restriction prohibits certain loopbacks from running at the same time. Valid
loopback combinations listed in Table 4-8 are identified by YES.

Table 4-8.

Valid Loopback Combinations

LLB

PLB

DLB

RLB

DCLB

DTLB

LLB

N/A

NO

YES

YES

NO

YES

PLB

NO

N/A

YES

NO

NO

YES

DLB

YES

YES

N/A

NO

YES

YES

RLB

YES

NO

NO

N/A

NO

YES

DCLB

NO

NO

YES

NO

YES
(on separate ports)

YES
(on separate ports)

DTLB

YES

YES

YES

YES

YES
(on separate ports)

YES
(on separate ports)