Table 4-2.

Device Health and Status Messages (1 of 2)

Message

Description

LOS at Net

A Loss Of Signal condition (175 consecutive zeros) has been
detected on the network interface. The condition is cleared when
the density of ones to zeros received is 12.5%.

LOS at DTE

A Loss Of Signal condition (175 consecutive zeros) has been
detected on the DTE Drop/Insert (DSX-1) interface. The condition
is cleared when the density of ones to zeros received is 12.5%.

OOF at Net

An Out Of Frame condition (2 out of 4 frame synchronization bits in
error) has been detected on the network interface. The condition is
cleared when a reframe occurs.

OOF at DTE

An Out Of Frame condition has been detected on the DTE
Drop/Insert (DSX-1) interface. The condition is cleared when a
reframe occurs.

AIS at Net

An Alarm Indication Signal (unframed all ones signal) is being
received by the network interface.

AIS at DTE

An Alarm Indication Signal is being received by the DTE
Drop/Insert (DSX-1) interface.

EER at Net

An Excessive Error Rate condition has been detected on the
network interface (the bit error rate has exceeded the configured
threshold for ESF framing). The condition is cleared when the error
rate falls below the threshold value.

Yellow at Net

A Yellow Alarm signal is being received by the network interface.

Yellow at DTE

A Yellow Alarm signal is being received by the DTE Drop/Insert
(DSX-1) interface.

OOF at Prt

n

An Out Of Frame condition has been detected on data port Prt

n

(where

n is the port number). This condition only occurs if the

synchronous data port’s Embedded Data Link (EDL) is enabled
(only available for 2-port and 4-port DSU/CSUs).

EER at Prt

n

The error rate of the received signal has exceeded the configured
threshold for data port Prt

n (where n is the port number). This

condition only occurs if the synchronous data port’s Embedded
Data Link (EDL) is enabled (only available for 2-port and 4-port
DSU/CSUs). The condition is cleared when the error rate falls
below the synchronous data port’s configured threshold value.

PORT IP Down

The IP management link is in a down state for

PORT (where PORT

is COM, MODEM, or AUX). This condition occurs if the

PORT is

configured for Mgmt, and communication between the
management system and the DSU/CSU is not currently possible for
this port. For the AUX port, this condition is detected only when a
device reset or power-up occurs.

Selftest failed

A failure was detected during the power-on self-test. Select STest
(in the Stat branch) to display more information about the failure.

DevFail

xxxxxxxx

An internal error has been detected by the operating software. An
8-digit code appears for use by service personnel. The condition is
cleared by resetting the device.

Download failed

A download attempt was interrupted and failed to complete. The
condition is cleared by resetting the device.