Maintenance

4-8

3160-A2-GB21-80

March 1999

"

Procedure

To clear the performance registers:

1. From the top-level menu screen, press the

key until the Ctrl selection

appears on the screen.

2. Select Ctrl.

3. From the Control screen, press the

key until the ClrReg selection

appears on the screen.

4. Select ClrReg.

F1

Control:
Rel

LED

ClrReg

F2

F3

5. From the Clear Prf Regs screen, press F1 to clear the User registers.

F1

Clear Prf Regs:
User

Prt1

Prt2

F2

F3

If you selected User, the User performance registers are cleared, all
accumulators are reset to zero, and all status registers are cleared. The
current interval timer, the number of valid intervals count, and the total
24-hour counts are reset to zero. The

Command Complete

message then

appears.

Table 4-3.

Performance Registers (1 of 3)

Register

Interval Description

Totals Description

Event

ESF error events counter. An error
event is an ESF frame with either a
Cyclic Redundancy Check (CRC)
error or an Out Of Frame (OOF)
event. The maximum count is
65,535. This register is only reset
as a result of a reset command
from the network. This register is
valid for the current interval only.

N/A

CurTimer

Current interval timer. This register
records the number of seconds in
the current 15-minute interval. The
maximum is 900 seconds. This
register is valid for the current
interval only.

N/A