Installing the redundant – 48 vdc power supply, Installing the redundant – ā 48 vdc power supply – Paradyne 3160 User Manual

Page 31

Advertising
background image

Installation

2-7

3160-A2-GB21-80

March 1999

Installing the Redundant –

ā48 Vdc Power Supply

To install the DSU/CSU using a redundant – 48 Vdc SELV power supply, refer to
Figure 2-11 and use the following procedure.

"

Procedure

To install the redundant – 48 Vdc power supply:

1. Connect the black wire to the – 48 Vdc return source B.

2. Connect the red wire to the – 48 Vdc return source A.

3. Connect the green wire to a suitable ground.

4. Connect the orange wire to the – 48 Vdc input source B.

5. Connect the blue wire to the – 48 Vdc input source A.

6. Cut the white wire off at the outer insulation.

7. Plug the power connector into the DSU/CSU.

1

2

3

4

5

6

BLACK

RED

GREEN

WHITE

ORANGE

BLUE

– 48 VDC RETURN B

– 48 VDC RETURN A

GROUND

– 48 VDC INPUT B

– 48 VDC INPUT A

99-14300-02

X

DSU/CSU POWER

PLUG

TO CUSTOMER-SUPPLIED BATTERY

Figure 2-11.

– 48 Vdc Redundant Source Power Supply Pinouts