Figure 4-2, Described in, Table 4-7 – Paradyne 3160 User Manual

Page 120

Advertising
background image

Maintenance

4-18

3160-A2-GB21-80

March 1999

LINE

RECEIVER

INTERNAL

CIRCUITRY

LINE

RECEIVER

TERMINAL

EQUIPMENT

(DTE)

NETWORK

NET

Out

EQPT

In

MON

Out

NET

In

EQPT

Out

MON

In

496-14875

Mon Jack: EQPT

Mon Jack: NET

Mon Jack: EQPT

Mon Jack: NET

(Selectable)

(Selectable)

Figure 4-2.

Test Jack Block Diagram

Table 4-7.

Test Jack Functions

Test Jack Name

Function

NET In
(Network In)

A break-in test jack that allows a signal to be inserted toward
the network by external test equipment.

NET Out
(Network Out)

A break-in test jack that interrupts the signal coming from the
network and allows it to be terminated by the external test
equipment.

EQPT In
(Equipment In)

A break-in test jack that allows a signal to be inserted toward
the terminal equipment (DTE) by external test equipment.

EQPT Out
(Equipment Out)

A break-in test jack that interrupts the signal coming from the
terminal equipment (DTE) and allows it to be terminated by
the external test equipment.

MON In
(Monitor In)

A monitor jack that is controlled by the Mon (Monitor) branch
of the menu tree. If it is set to EQPT (the default), this jack
monitors the signal going into the terminal equipment (DTE).
If it is set to NET, this jack monitors the signal going into the
network.

MON Out
(Monitor Out)

A monitor jack that is controlled by the Mon (Monitor) branch
of the menu tree. If it is set to EQPT (the default), this jack
monitors the signal coming from the terminal equipment
(DTE). If it is set to NET, this jack monitors the signal coming
from the network.