SNMP MIB Objects

E-16

3160-A2-GB21-80

March 1999

Near End Group – “dsx1CircuitIdentifier” Object (dsx1ConfigEntry 8)

This object is only supported on the Net T1 Interface.

Near End Group – “dsx1LoopbackConfig” Object (dsx1ConfigEntry 9)

This object specifies the loopback state of the T1 interfaces. Only the following
values are supported by the DSU/CSU.

H

dsx1NoLoop(1) – The T1 interface is not in a loopback state.

H

dsx1PayloadLoop(2) – Specifies that a Payload Loopback (PLB) is active for
the network interface or a Repeater Loopback (RLB) is active for the DTE
Drop/Insert (DSX-1) interface.

H

dsx1LineLoop(3) – Specifies that a Line Loopback (LLB) is active for the
network interface or a DTE Loopback (DLB) is active for the DTE Drop/Insert
(DSX-1) interface.

Near End Group – “dsx1LineStatus” Object (dsx1ConfigEntry 10)

This object specifies the line (alarm) status of the T1 interfaces. Only the
following values are supported by the DSU/CSU. More than one value may be
active at a time.

H

dsx1NoAlarm(1) – No alarm present.

H

dsx1RcvFarEndLOF(2) – A yellow alarm signal is being received.

H

dsx1RcvAIS(8) – An Alarm Indication Signal (AIS) is being received.

H

dsx1LossOfFrame(32) – An Out Of Frame condition has persisted for more
that 2.5 seconds (i.e., Red Alarm).

H

dsx1LossOfSignal(64) – A Loss of Signal condition has persisted for more
that 2.5 seconds (i.e., Red Alarm).

H

dsx1LoopbackState(128) – The near end of the T1 interface is in a loopback
state.

H

dsx1Other Failure(4096) – An Excessive Error Rate (EER) has been
detected on the network interface.

Near End Group – “dsx1SignalMode” Object (dsx1ConfigEntry 11)

This object specifies whether Robbed Bit Signaling (RBS) is being used. This
object differs from the MIB definition in that it is “read-only” (not read/write) for
DSU/CSUs. Only the following values are supported by the DSU/CSU.

H

none(1) – No signaling is being used on this interface.

H

robbedBit(2) – Robbed Bit Signaling is being used on at least one DS0 on
this T1 interface.