Technical specifications, Overview, Appendix b – Paradyne 3160 User Manual

Page 143

Advertising
background image

B-1

3160-A2-GB21-80

March 1999

Technical Specifications

B

Overview

The technical specifications for the standalone DSU/CSUs are listed in Table B-1.
The technical specifications for the carrier-mounted DSU/CSUs are listed in the
ACCULINK 3151 CSU and 3161 DSU/CSU General Information Guide.

Table B-1.

Models 3160/3164/3165/DSU/CSU’s Technical Specifications (1 of 2)

Specifications

Criteria

POWER REQUIREMENTS
Typical:

AC Power Module

Optional:

+24 Vdc

– 48 Vdc

– 48 Vdc Redundant

Refer to the labeling on the ac power module for input
requirements

+20 Vdc to +32 Vdc, 0.50A

–38 Vdc to – 60 Vdc, 0.25A

–38 Vdc to – 60 Vdc, 0.25A

POWER CONSUMPTION
AND DISSIPATION

3160:
6.5 watts, 22.1 Btu per hour at +24 Vdc;
6.2 watts, 21.3 Btu per hour at – 48 Vdc
8.7 watts, 29.7 Btu per hour at 100 Vac (includes
external transformer)
9.2 watts, 31.4 Btu per hour at 120 Vac (includes
external transformer)

3164, 3165:
12.0 watts, 41 Btu per hour at +24 and – 48 Vdc
16.0 watts, 55.0 Btu per hour at 115 Vac (includes
external transformer)

ENVIRONMENT

Operating Temperature
Storage Temperature
Relative Humidity Shock and
Vibration

32

°

F to 122

°

F (0

°

C to 50

°

C)

– 4

°

F to 158

°

F (–20

°

C to 70

°

C)

5%—95% (noncondensing)
Withstands normal shipping and handling

Advertising
This manual is related to the following products: