Basic Measurements

1760 Series Component Waveform/Vector Monitor User Manual

4-16

Lightning Measurements

The Lightning display gives indication of absolute and rela-
tive amplitudes and relative timing of the three components.
For a Lightning display, apply color-difference signals (Y, P

B

and P

R

) to the rear panel CH-A1, A2, and A3 (or CH-B1, B2,

and B3) connectors. Push the front-panel

LIGHTNING

button.

The instrument is forced to A123 input display (it can be
changed to B123).

Use the

CONFIG—FORMAT

menu (page 3-21) to set

DISPLAY

to

LIGHTNING

, and select the appropriate format for your

system. Lightning is most useful in the color difference for-
mats:

SMPTE, EBU, BETA, and MII

. (Selecting

GBR

will pro-

vide a square display.) Use the

CONFIG—VECTOR

menu to

select 75% or 100% bars. This will change the size of the
electronic graticule to accommodate the input signal. Push

CLEAR MENU

to clear the menu readout.

Channel 2 is compared to Channel 1 in the top half of the
display; Channel 3 is compared to Channel 1 in the lower
half. (See Figure 4-14.)

525/60

C

M

B

R

M

C

G

B

R

G

YL

YL

White

Black

Setup

White

Figure 4-14. Lightning display showing correct timing.