Operator’s Checkout Procedure

1760 Series Component Waveform/Vector Monitor User Manual

2-26

VECTOR PHASE

Figure 2-18. PAL SCH display.

14. Lightning Display

For a Lightning display, select the Y, B--Y, R--Y format on
the signal generator. Enter the

CONFIG

menu and select

FORMAT

. Select the proper format for your signal source

(GBR, SMPTE/EBU, BETA

or

MII).

Under

DISPLAY,

select

LIGHTNING

. Leave the configuration menu selected.

Select

LIGHTNING

display mode. The display should be

similar to Figure 2-19.

Under

DISPLAY

,

select

DIAMOND

. Select 100% Bars on the

signal generator. Figure 2-20 shows a sample display. Exit
the configuration menu. Information on using the Lightning
and Diamond displays appears on page 4-16.