Vector, Format – Tektronix 1760 User Manual

Page 89

Advertising
background image

Using the Menus

1760 Series Component Waveform/Vector Monitor User Manual

3-21

H

A123

and

B123

When

COMPOSITE

is se-

lected, the instrument’s internal reference is the
input channel currently selected for display. For

COMPONENT,

the internal reference is

A1

when

A123

is selected, and

B1

when

B123

is selected (sync is

present only on the first channel).

VECTOR

H

BARS

— The instrument can be configured to accept

75% or 100% amplitude color bar signals

. Dual-

Standard instruments allow color bar signal ampli-
tudes to be set for NTSC and for PAL operation.

H

SETUP

— (NTSC operation only) Configures the

instrument to accept signals with or without setup.

H

PAL

— (PAL operation only) When +V is chosen,

the phase reference of the --V lines is inverted, then
shown as an overlay on the +V lines to provide a
comparison display. +V shows +V and --V on
alternate lines.

H

TEST

— Used by service personnel; refer to the

service manual.

FORMAT

H

CONFIG—FORMAT

is used to to select the configura-

tion of signals used for interconnection of equip-
ment. Available signal formats are:

GBR

,

SMPTE/

EBU

,

BETA

, and

MII

. When viewed as a waveform

parade display, GBR signals may be displayed in
either GBR sequence or RGB sequence, as selected
through the

GBR PARADE GBR/RGB

menu.

Table 3-1 shows valid format selections.

H

CONFIG—FORMAT

is also used to select which

display

(LIGHTNING

or

DIAMOND)

is present when

the front-panel

LIGHTNING

button is pressed.

Advertising