Functional Overview

1760 Series Component Waveform/Vector Monitor User Manual

3-3

Lightning

The front-panel

LIGHTNING

button is used for both the Light-

ning display and the Diamond display. For Lightning dis-
play, use the

CONFIG—FORMAT

menu (page 3-21) to set the

DISPLAY

to

LIGHTNING

and select the appropriate format for

your system. Push

CLEAR MENU

to clear the menu readout.

Selecting Lightning mode forces the instrument to A123 in-
put display; it can be changed to B123. Apply component
signals Y, P

B

and P

R

to the rear panel connectors for CH-A1,

A2, and A3 or CH-B1, B2, and B3. Procedures for using the
Lightning display can be found in the Operator’s Checkout
and on page 4-16.

NOTE

A123 (or B123) must be configured as a compo-
nent input. See

CONFIGURE

menu, page 3-20.

Diamond

For a Diamond display, push the

LIGHTNING

button and use

the

CONFIG—FORMAT

menu to set

DISPLAY

to

DIAMOND.

Apply a component signal to the rear panel connectors for
CH-A1, A2, and A3 or CH-B1, B2, and B3. The Diamond
display evaluates the GBR signal for gamut limit violations
and color errors due to gamma correctors. Signals which are
inside the electronic diamond graticule are within gamut lim-
it. For signals outside the diamond, the graticule is labeled
with G, B, and R to determine the color problem area.

NOTE

A123 (or B123) must be configured as a compo-
nent input. See

CONFIGURE

menu, page 3-20.