background image

Basic Measurements

1760 Series Component Waveform/Vector Monitor User Manual

4-21

Using the Bowtie Display

When used with the Bowtie signal, the Bowtie display is a
high-resolution timing indicator.

Route a Bowtie test signal from the generator, through the
equipment under test, and connect to the 1760--Series rear-
panel CH-A1, A2, and A3 connectors. Use caution when
deciding where the Bowtie signal is routed; when transcoded
to GBR or encoded to composite, it produces and illegal sig-
nal with potential unwanted side effects.

For a Bowtie display, push the 1760--Series front-panel

BOW-

TIE

button. A two-line display of component signals will be

present: line one (left half of display) shows CH-1 minus
CH-2 and line two shows CH-1 minus CH-3. See
Figure 4-17.

If the bowtie patterns have a sharp null, and the null is lo-
cated in the center of each line, both timing and relative am-
plitudes are correct. Relative amplitude errors will decrease
the depth of the null. Interchannel timing errors will move
the position of the null.

Figure 4-17. Bowtie display showing a sharp null.