Functional Overview

1760 Series Component Waveform/Vector Monitor User Manual

3-5

Displaying a Signal

Inputs

There are eight rear-panel loop-through inputs, which may
eliminate the need for an external routing switcher. The in-
puts can be displayed singly or in combination.

Without

PARADE

or

OVERLAY

selected, only one input selec-

tion can be made at a time. Each input channel button (in-
cluding

A123 / B123

) toggles between

A

and

B

,

and is

cancelled when another input button is pressed.

With

PARADE

or

OVERLAY

selected, the input channels can be

displayed in combination. Pushing an input channel button
sequences through the labeled channels, both, then off. Push-
ing another input button does not cancel the current selec-
tion, but adds to it. To return to “single input” operation,
push the

PARADE/OVERLAY

button until it is off (LED is no

longer lighted).

A123 / B123

Selecting

A123

provides a side-by-side display of the

CH-A1,

CH-A2,

and

CH-A3

inputs (

B123

displays the

CH-B1, CH-B2,

and

CH-B3

inputs). This is designed for monitoring component

signals.

Parade

Selecting

PARADE

displays the input channels last selected

for

PARADE

,

allowing a custom configuration of inputs. In

PARADE

mode, the

LINE/FIELD

button offers only two choices:

one line and one field.

PARADE

allows up to four channels to be displayed side-by-

side. Additional channels will be overlaid.