Operator’s Checkout Procedure

1760 Series Component Waveform/Vector Monitor User Manual

2-19

10 S/DIV

FLAT

LUM

CHROM

DIFF

R--Y

SCH R--Y

F+L

F+L+C

Figure 2-8. Two-Line CHROM filter display of color bar signal.

Select

F+L+C

(

FLAT

plus

LUM

plus

CHROM

). The display is

similar to the

F+L

display, with the chrominance-filtered

signal added on the right.

Select

DIFF

. Select the generator 5-step staircase signal. The

differentiated-step filtered display appears similar to
Figure 2-9.

Select

R---Y

. This provides a demodulated chrominance-vs.-

time display. Use the right bezel control to adjust vector
phase. See Figure 2-10.

Select

SCH R---Y

(Option SC only). This provides a demodu-

lated SCH sync-locked oscillator display, useful for viewing
SCH variations versus time. A sample NTSC display is
shown in Figure 2-11. NTSC signals can be viewed in either
line or field sweeps. For PAL applications, view the signal in
two-field sweep (see Figure 2-12). Use the right bezel control
to adjust vector phase.

Exit the filter menu. Enter the menu again and note that the
filter selections are unchanged. Select

FLAT

. Exit the menu.