Operator’s Checkout Procedure

1760 Series Component Waveform/Vector Monitor User Manual

2-28

15. Bowtie Display

For a Bowtie display, select the Channel Timing signal from
the generator. Select

BOWTIE

display mode on the 1760--Se-

ries. The display should appear similar to Figure 2-21.
Information on making measurements with the Bowtie
display appears on page 4-21.

Figure 2-21. Bowtie display.

This concludes the

Operator’s Checkout Procedure.