6 ionisation processing – Tyco MX4428 User Manual

Page 119

Advertising
background image

Document: LT0273

MX4428 MXP Engineering / Technical Manual

Device

Processing

Issue 1.5

24 March 2006

Page 9-9

9.6

IONISATION

PROCESSING

The smoke reading of the detector is returned in two parts as inputs AI0 and AI1 of the
device ASIC. In the MXP the average value of AI0 and AI1 is used for all calculations, so
that all returned values to the MX4428 lie within the range of 0 – 255. (Note that TEPG
literature refers to the sum of the two inputs.)

The processing is shown in Figure 9.6. The tracked value is initialised by setting it to a high
value (100) when the MXP or detector powers up, and allowing the tracked value to
increment / decrement by 1 for each of the first 4 minutes.

Exponential
Filter

Slope
Limiter

Very Slow Slope
Limiter
(1 step per Tracking Interval)

TV = Tracked Value
= Assumed Clean Air Value

Raw
Value

+

+

+

+

-

-

-

-

Alarm Threshold

Alarm

Subtractor

Subtractor

Comparator

Comparator

CV

PreAlarm Threshold

PreAlarm

SLV

Filter Divisor

Step Limit

Figure 9.6 Ionisation Detector Processing