ZyXEL Communications P-202 User Manual

Page 106

Advertising
background image

P-202H Plus v2 Support Notes

When calling back to a remote node the outgoing user information (username
and password) are configured in menu 11.1, Remote Node Profile. While calling
back to a dial-in user, the outgoing user information are configured in two fields in
menu 13, O/G Login and O/G Password.

Setup the P-202H Plus v2 for calling back to a remote node

Setup the P-202H Plus v2 for calling back to a dial-in user

Setup the P-202H Plus v2 for calling back to a remote node

Generally, there are several settings must be checked when using the CLID
callback. They are:

ƒ

The 'CLID Authentication' setting in menu 13 must be configured as
'Required' or 'Preferred'.

ƒ

The 'Remote CLID' setting in menu 11.1 must be entered for the CLID
authentication.

ƒ

The 'Callback' setting in menu 11.1 must be toggled to 'Yes'.

ƒ

The 'Outgoing user information' in menu 11.1 must be entered.

ƒ

The 'Outgoing Phone number' in menu 11.1 must be entered.

The following SMT only show the main settings of the CLID callback, you can
refer to the user's manual or the support note for the other settings.

1. Toggle the 'CLID Authen' option in menu 13 to 'Required'.


Menu 13 - Default Dial-in Setup

Telco Options: IP Address Supplied By:
CLID Authen= Required Dial-in User= Yes
IP Pool= No
PPP Options: IP Start Addr= N/A
Recv Authen= CHAP/PAP IP Count(1,2)= N/A
Compression= Yes
Mutual Authen= No
O/G Login= N/A Session Options:
O/G Password= N/A Edit Filter Sets= No
Multiple Link Options:
Max Trans Rate(Kbps)= 128

Callback Budget Management:
Allocated Budget(min)=

All contents copyright © 2006 ZyXEL Communications Corporation.