P-202H Plus v2 Support Notes

Version= RIP-2B

Edit IP Alias= No

2. Remote Node Setup in SMT Menu 11


Menu 11.1 - Remote Node Profile

Rem Node Name= LAN2 Edit PPP Options= No
Active= Yes Rem IP Addr= 203.66.113.1
Call Direction= Outgoing Edit IP= No

Incoming: Telco Option:
Rem Login= Transfer Type= 64K
Rem Password= Allocated Budget(min)=
Rem CLID= N/A Period(hr)=
Call Back= N/A Schedules=
Outgoing: Carrier Access Code=
My Login= test Nailed-Up Connection= No
My Password= ******** Toll Period(sec)= 0
Authen= CHAP/PAP Session Options:
Pri Phone #= 5007025 Edit Filter Sets= No
Sec Phone #= Idle Timeout(sec)= 100

Press ENTER to Confirm or ESC to Cancel:

Key Settings:

o

Select the 'Active' field to 'Yes'

o

Select the 'Call Direction' to 'Outgoing'

o

Enter the correct node account in 'My Login' and 'My Password'
fields

o

Enter the phone number of the remote router in the 'Pri Phone #'
field

o

Enter the IP address of the remote router in 'Rem IP Addr' field

o

Enter the idle timer in the 'Idle Timeout' field for dropping the call if
there is no data traffic between the two remote nodes

P-202H Plus v2 2 Setup

1. Ethernet Setup in SMT Menu 3