Chapter 5: Subsystem Maintenance

Subsystem Maintenance

5-7

Step 2.

Install the BBU module onto the replacement controller. You

may need to install a DIMM module to your replacement

controller if it comes without a pre-installed module.

Step 3.

Install the replacement controller into the subsystem by

pushing it into the module slot. Carefully push it in until you

feel the contact resistance. Use slightly more force and when

the controller faceplate is almost aligned with the chassis rear

panel, pull up the ejection levers to secure the controller into

chassis.

Figure 5-4: Installing a Replacement Controller

Step 4.

Fasten the previously removed retention screws to secure the
ejection levers.

Step 5.

Re-attach all the cables that were removed. These include the
host FC cables, SAS expansion link, the Ethernet cable, and
the serial port cables.