6 power off procedure – Rorke Data Galaxy HDX2 GHDX2-2430S-24F4D User Manual

Page 94

Advertising
background image

Chapter 4: Subsystem Connection and Operation

Subsystem Connection and Operation

4-27






4.6

Power Off Procedure

To power off the subsystem, please follow these steps:

NOTE:

When powering off the subsystem, please ensure that no time-consuming

processes, like a “logical drive parity” check or a “Media Scan,” are running.

Step 1.

Stop I/O access to the system.

Use the software provided on the host computer to stop all I/O

accesses to the subsystem. Please refer to the documentation

that came with your application servers and operating systems.

Some operating systems may require “unmounting” disk

volumes (mapped LUNs) before powering off the array.

Step 2.

Flush the cache.

Usually the cached writes will be distributed in a short time.

You may also use the “Shutdown Controller” firmware

function to flush all cached data. This prepares the RAID

subsystem to be powered down.

Step 3.

Turn off the power.

Turn off the power switch at the rear panel of the RAID

subsystem. Once the RAID subsystem has been powered off,

other devices connected to the subsystem may be powered

down.

Advertising