Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual

Introduction

1-12

2

1. Warning messages are issued.

2. The subsystem is temporarily held in an idle state.

3. The firmware forces the subsystem to stop serving host

I/O requests.

4. After the failed PSUs are replaced, array administrators

should manually turn the power switch off and then on.

5. If the subsystem is powered on with only one PSU, the

firmware will start the initialization process but stays idle

until at least one other PSU is added.

Table 1-1: Power Supply Safety Restrictions

1.2.8 Cooling

Modules

These Galaxy 24 bay subsystems come with two (2) hot swappable, redundant, dual-fan

cooling modules. Two (2) 8cm

blowers are housed in each cooling module and provide

ventilation airflow from the front to the rear of the subsystem, extracting the heat

generated by the SATA hard drives and other components.

Intelligent Dual Speed Operation

The fans in the cooling module operate with two rotation speeds. Under normal operating

conditions, the cooling fans run at the low speed, which is sufficient for maintaining an

efficient airflow across components. Under the following conditions, the cooling fans

automatically increase their rotation speed to increase the airflow:

1. Component Failure: if a cooling fan, PSU, or temperature sensor fails, the

remaining cooling fan(s) automatically raises its rotation speed.

2. Elevated Temperature: if the temperature breaches the upper threshold set for any

of the interior temperature sensors, the cooling fans automatically raise its rotation

speed.

3. During the initialization stage, the cooling fans operate at the high speed and

return to low speed once the initialization process is completed and no erroneous

condition is detected.