Chapter 2 Hardware Installation

Hardware Installation

2-9

Figure 2-4: Accessing a DIMM Module

Step 5. Install the replacement DIMM module. Carefully remove the

replacement module from its anti-static bag. Grasp the module by

edges. Make sure the white, plastic ejectors on the sides of DIMM

socket are open. Carefully align the DIMM module to the socket.

Pressing firmly on both ends, push the module into the socket until the

ejectors return to the closed position.

Figure 2-5: Accessing a DIMM Module

Step 6. Install the controller and the BBU module (if installed). Proceed

with the following to install the controller:

1. Insert the controller into the respective module slot with the

ejector levers at the lowest position.

2. Push the controller in until you feel contact resistance with its

back-end connectors. Use slightly more force to engage the back-

end connectors.