Chapter 2 Hardware Installation

Hardware Installation

2-17

impact during installation may damage your hard drives.

Hard drives for the subsystem must be purchased separately. When purchasing the hard

drives, the following factors should be considered:

ƒ

Capacity (MB/GB): Use drives with the same capacity. RAID arrays use a “least-

common-denominator” approach meaning the maximum

applicable capacity from each member drive in the array is

the maximum capacity of the smallest drive.

ƒ

Profile:

The drive trays and bays of the system are designed for 3.5-

inch wide x 1-inch high hard drives.

ƒ

Drive type:

The Galaxy subsystem complies with SATA-II interface hard

drives.

2.8.3 Drive Installation

NOTE:

Although your drives have been preinstalled and tested you may need to replace a

faulty drive. Use the following procedure to replace a faulty drive.


Step 1.

Place the hard drive into the drive tray. Make sure the hard drive is

oriented that the drive’s SATA connector is facing the open side of the

drive tray and its label side facing up.