Chapter 1: Introduction

1-9

The dual-controller subsystem comes with a serial port Y-cable that allows you to

access a surviving controller in the event of controller failure without physically

changing the connection.

TIPS:

Connect both Ethernet ports (if you are using a dual-controller subsystem) to

the Ethernet ports of your network switch.

The Ethernet port on a non-dominant (secondary) controller will stay idle until

the occurrence of primary controller failure.

ƒ

Ethernet port: A single 10/100BaseT Ethernet port is used for local/remote

management over LAN/WAN. For a dual-controller configuration, connect the

Ethernet ports on both RAID controllers to your local network. The Ethernet port on

a non-dominant (stand-by, usually the controller in the lower slot) controller will

remain idle until a dominant, primary controller fails and the management service is

transferred to the surviving controller.

ƒ

Disk Drive Channels: All models come with twenty-four (24) SATA drive channels

that are interfaced thorough a backplane to the hard disk drives.

1.2.5 DIMM

Module

Each controller module comes with a preinstalled 512MB DDR RAM DIMM module

mounted on the controller board within a metal chassis. The controller module supports

memory modules with sizes from 512MB to 2GB.

1.2.6 BBU

Module

The BBU can sustain cached data for days during a power failure. If power outage

occurs, the BBU supplies power to sustain the unfinished writes in cache memory.