Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual

4-24

Subsystem Connection and Operation

Figure 4-13: Power Switch

CAUTION!

Although the PSUs are redundant and the subsystem can withstand a

single PSU failure, it is advisable to replace a failed PSU immediately.

The subsystem will be held in an idle state if two PSUs have already failed

in the subsystem.

Step 4.

Power on the host computers.

The host computers are the last devices that are turned on.

Please refer to the documentation that came with your host

computers to see their own power on procedures.

4.5.3

Power On Status Check

Once the subsystem has been powered on, the status of the entire subsystem

should be checked to ensure that all components are receiving power and

functioning without complications or malfunctions.

…

Controller module LEDs – The controller ready, host and drive ports

active LEDs should all flash green after a successful initialization.

…

Drive tray LEDsThe blue LED for all the drive trays (that contain

hard drives) should light up, showing that there is power.

…

LCD panel LEDs The blue LED on the LCD panel should be lit,

indicating that power is supplied to the system.

…

Firmware and RAIDWatch – The overall status of the system can be

checked using the firmware or the RAIDWatch GUI.