Cooling module maintenance – Rorke Data Galaxy HDX2 GHDX2-2430S-24F4D User Manual

Page 108

Advertising
background image

Chapter 5: Subsystem Maintenance

Subsystem Maintenance

5-13

Step 6. Insert and fasten the retention screw underneath the

extraction handle to secure the module.

Step 7. Install the cable clamp assembly (if used).




5.5. Cooling

Module

Maintenance

5.5.1

Notes on Cooling Module Maintenance

ƒ Two redundant cooling modules: The subsystem is equipped with two

redundant, hot swappable, dual-fan cooling modules located above the PSU

modules. These cooling modules control the internal operating temperature

of the subsystem and therefore their working integrity should be maintained

at all times.

ƒ Detecting a failed cooling fan module: If a cooling module fails, you can

choose to be notified of the failure by the LEDs located at the back of the

module, an audible alarm, the firmware terminal access, the RAIDWatch

Panel View, or the various event notification methods.

Shown below are the locations of cooling fans:

Figure 5-10: Locations of the Subsystem Cooling Fans

NOTE:

To reduce the risk of system down time, replace a cooling fan/PSU module

even when only one cooling fan fails within. Replacing a single cooling fan

within each module may take several minutes and is not an operation

completed at the installation site.