Rorke Data Galaxy HDX2 GHDX2-2430S-24F4D User Manual

Page 71

Advertising
background image

Galaxy GHDX2-2430S/R-24F4D Installation and Hardware Reference Manual

4-4

Subsystem Connection and Operation

Figure 4-1: Drive Mechanical Speed and Logical Drive Speed

There are other considerations. For example, a spare drive carries no data

stripes and will not contribute to disk-level performance. Refer to the

documentation that came with your hard drives for performance data.

Follow all the Fibre Channel specifications when cabling. Pay attention to

signal quality and avoid electronic noise from adjacent interfaces.

The disk drives included in the same logical array should have the same

capacity, but it is preferred that all disk drives within a chassis have the

same capacity. Even disk drives of the same model name may carry

different block numbers. One way to get around this issue is to tune down

the “Maximum Drive Capacity” to a lower number. Please refer to your

firmware operation manual for details.

A spare drive should have a minimum capacity equivalent to the largest

drive that it is expected to replace. If the capacity of the spare is smaller

than the capacity of the drive it is expected to replace, then the controller

will not proceed with the failed drive rebuild.