Chapter 1: Introduction

1-11

Figure 1-11: PSU Module

Each PSU module comes with a power socket for power cord plug-in. All three power

supplies are turned on and off using a single power switch on the enclosure chassis. Each

PSU also comes with two (2) embedded cooling fans to provide sufficient airflow across

its heat-generating components and one (1) LED to indicate the PSU status. An extraction

handle makes it easier to install or remove the PSU from the subsystem. While a PSU

may be removed when the system is still online, this should only be done if the PSU has

failed and needs to be replaced.

A retention screw through the extraction handle secures the PSU to the chassis. If the

PSU needs to be removed, the retention screw must be removed first. After installing a

new PSU module, make sure that the retention screw has been firmly secured. The

shipping package contains adjustable cable clamps that can be used to secure power cord

connections.

PSU specifications are shown in Appendix A.

Power Supply Safety Restrictions

No. of Failed PSUs

Responses and Preventive Actions

1

1. Warning messages are issued.

2. Cached data is flushed to the hard drives (also depends on

the Event Triggered configuration settings of the

firmware).

3. If previously configured to the Write-back mode, the

caching mode is automatically switched to the

conservative Write-through mode.