Chapter 2 Hardware Installation

Hardware Installation

2-3

Step 4. Verification of hard drive installation into the drive trays.

Although SATA-II interface hard drives have been installed into drive

trays for you, follow this procedure to replace individual hard drives.

(See Section 2.7)

Step 5. Install the drive trays into the enclosure. Note that the drive trays

used in single- or redundant-controller subsystems are different. Make

sure not to mix the drive trays. A redundant-controller subsystem

requires the MUX boards on its drive trays.

Step 6. Connect the cables. Use the supplied power cords to connect the

subsystem to power mains. It is recommended to connect power cords

to separate and independent power sources, e.g., UPS systems, for

higher redundancy. Make sure your subsystem is electrically

grounded.

It is also recommended to use the included cable clamps to prevent

accidental disconnection of the power cords. Use separately purchased

Fibre Channel optical cables and transceivers to connect the host ports

to your Fibre Channel storage network or directly to the host

computers. (See Chapter 4)

SAS expansion JBODs come with SAS 4x, wide link cables.

Step 7. Power up. Once all of the components have been properly installed

and all the cables properly connected, the subsystem can be powered

up and the RAID array configured. (See Chapter 4)

2.4.1 Installation Procedure Flowchart

Figure 2-1 shows a flowchart of the installation procedure. As you complete each step,

check off the “Done” box on the right. Please use this flowchart in conjunction with the

instructions that follow.