Key Behavior

TAKE: this key is operational in ARM mode.

RECORD: the remote does not beep if the CAM key refers to an empty block.

RECORD: pressing this key while the current block is recording does not send any
command to the camera.

CLEAR: this key has no effect.

Cue points management

When a new ARM/REC command is issued on a block, all its cue points are cleared.

If the Last Cue command cannot access the desired TC-pre-roll, the player remains
on the current cue point.

If the Last Cue command refers to a TC that does not exist anymore, the player
jumps to the beginning of the current memory block.

Cue points can not be marked when working on several memory blocks.

Vision Research Camera

Application Start

At application start, the recording does not start automatically.

Configuration Parameter Values

Port = RS422 & Protocol = ASCII

Or Port = Ethernet & Protocol = TCP

The PGMSpeed parameter value 1000 is available.

Key Behavior

TAKE: this key is operational in any mode.

RECORD: the remote beeps if the CAM key refers to an empty block.

RECORD: pressing this key while the current block is recording clears all memory
blocks and starts recording on the first one.

CLEAR: press this key to delete the current memory block data.

206

9. Advanced Control Modes

EVS Broadcast Equipment S.A.

Issue 11.02.A July 2013

Advertising