Rainbow Electronics 71M6542G User Manual

Page 113

Advertising
background image

v1.1

© 2008–2011 Teridian Semiconductor Corporation

113

Name

Location

Rst Wk Dir Description

DIO_PV

2457[6]

0 – R/W Causes VARPULSE to be output on pin SEGDIO1, if LCD_MAP[1] = 0.

DIO_PW

2457[7]

0 – R/W Causes WPULSE to be output on pin SEGDIO0, if LCD_MAP[0] = 0.

DIO_PX

2458[7]

0 – R/W Causes XPULSE to be output on pin SEGDIO6 , if LCD_MAP[6] = 0.

DIO_PY

2458[6]

0 – R/W Causes YPULSE to be output on pin SEGDIO7 , if LCD_MAP[7] = 0.

EEDATA[7:0]

SFR 9E

0 0 R/W Serial EEPROM interface data.

EECTRL[7:0]

SFR 9F

0 0 R/W

Serial EEPROM interface control.

Status

Bit

Name

Read/

Write

Reset

State

Polarity Description

7

ERROR

R

0

Positive

1 when an illegal command
is received.

6

BUSY

R

0

Positive 1 when serial data bus is

busy.

5

RX_ACK

R

1

Positive

1 indicates that the
EEPROM sent an ACK bit.

EQU[2:0]

2106[7:5]

0 0 R/W

Specifies the power equation.

EQU

Watt & VAR Formula

(WSUM/VARSUM)

Inputs Used for Energy/Current

Calculation

W0SUM/

VAR0SUM

W1SUM/

VAR1SUM

I0SQ
SUM

I1SQ
SUM

0

VA*IA
1 element, 2W 1

φ

VA*IA

VA*IB

1

IA

IB

1

1

VA*(IA-IB)/2
1 element, 3W 1

φ

VA*(IA-IB)/2

IA-IB

IB

2

VA*IA + VB*IB
2 element, 3W 3

φ Delta

VA*IA

VB*IB

IA

IB

Note:

1. Optionally, IB may be used to measure neutral current.

71M6542F only

Advertising