5.3.6 CE Front End Data (Raw Data)

Access to the raw data provided by the AFE is possible by reading addresses 0-3, 9 and 10 (decimal) shown
in

Table 79

.

The MUX_SEL column in

Table 79

shows the MUX_SEL handles for the various sensor input pins. For

example, if differential mode is enable via control bit DIFFA_E = 1 (I/O RAM 0x210C[4]), then the inputs IAP
and IAN are combined together to form a single differential input and the corresponding MUX_SEL handle is
0. Similarly, the CE RAM location column provides the CE RAM address where the sample data is stored.
Continuing with the same example, if DIFFA_E = 1, the corresponding CE RAM location where the
samples for the IAP-IAN differential input are stored is 0 and CE RAM location is not disturbed.

The IB input can be configured as a direct-connected sensor (i.e., directly connected to the 71M654x) or as a
remote sensor (i.e., using a 71M6x01 Isolated Sensor). If the remote sensor is disabled by RMT_E = 0 and
differential mode is enabled by DIFFB_E = 1 (I/O RAM 0x210C[5]), then IBP and IBN form a differential
input with a MUX_SEL handle of 2, and the corresponding samples are stored in CE RAM location 2 (CE
RAM location 3 is not disturbed). If the remote sensor enable bit RMT_E = 1 and DIFFB_E = 0 or 1, then the
MUX_SEL handle is undefined (i.e., the sensor is not connected to the 71M654x, so MUX_SEL does not
apply, see

2.2 Analog Front End (AFE)

on page

12

), and the samples corresponding to this remote

differential IBP-IBN input are stored in CE RAM location 2 (CE RAM location 3 is not disturbed).

The voltage sensor inputs (VA and VB) do not have any associated configuration bits. VA has a MUX_SEL
handle value of 10, and its samples are stored in CE RAM location 10. VB has a MUX_SEL handle value of 9
and its samples are stored in CE RAM location 9.

Table 79: CE Raw Data Access Locations

ADC

Location

Pin

MUX_SEL Handle

CE RAM Location

DIFFA_E

DIFFA_E

0

1

0

1

ADC0

IAP

0

0

0

0

ADC1

IAP

1

1

RMT_E, DIFFB_E

RMT_E, DIFFB_E

0,0

0,1

1,0

1,1

0,0

0,1

1,0

1,1

ADC2

IBP

2

2

2

2

2*

2*

ADC3

IBN

3

3

There are no configuration bits for ADC9, 10

ADC9

VB†

9

9

ADC10

VA

10

10

Notes:
* Remote interface data.

71M6542F only.

5.3.7 FCE Status and Control

The CE Status Word, CESTATUS, is useful for generating early warnings to the MPU (

Table 80

). It contains

sag warnings for phase A and B, as well as F0, the derived clock operating at the fundamental input fre-
quency. The MPU can read the CE status word at every CE_BUSY interrupt. Since the CE_BUSY inter-
rupt occurs at 2520.6 Hz, it is desirable to minimize the computation required in the interrupt handler of
the MPU.

Table 80: CESTATUS Register

CE Address

Name

Description

0x80

CESTATUS

See description of CESTATUS bits in

Table 81

.


CESTATUS provides information about the status of voltage and input AC signal frequency, which are useful
for generating an early power fail warning to initiate necessary data storage. CESTATUS represents the