status flags for the preceding CE code pass (CE_BUSY interrupt). The significance of the bits in
CESTATUS is shown in

Table 81

.

Table 81: CESTATUS (CE RAM 0x80) Bit Definitions

CESTATUS

bit

Name

Description

31:4

Not Used

These unused bits are always zero.

3

F0

F0 is a square wave at the exact fundamental input frequency.

2

Not Used

This unused bit is always zero.

1

SAG_B

Normally zero. Becomes one when VB remains below SAG_THR for
SAG_CNT samples. Does not return to zero until VB rises above
SAG_THR.

0

SAG_A

Normally zero. Becomes one when VA remains below SAG_THR for
SAG_CNT samples. Does not return to zero until VA rises above
SAG_THR.


The CE is initialized by the MPU using CECONFIG (

Table 82

). This register contains in packed form

SAG_CNT, FREQSEL[1:0], EXT_PULSE, PULSE_SLOW and PULSE_FAST. The CECONFIG bit definitions are
given in

Table 83

.

Table 82: CECONFIG Register

CE

Address

Name

Data

Description

0x20

CECONFIG

0x0030DB00

1

0x00B0DB00

2

See description of the CECONFIG bits in

Table 83

.

1. Default for CE41A01 (71M6541D/F or CE41A04 (71M6542F) CE code for use with local

sensors.

2. Default for CE41B016201 and CE41B016601 codes that support the 71M6x01 remote

sensors.

Table 83: CECONFIG (CE RAM 0x20) Bit Definitions

CECONFIG

bit

Name

Default Description

23

Reserved

0

When this bit is set, control of temperature compensation is
enabled for the 71M6x01 Isolated Sensor Interface.

22

EXT_TEMP

0

When 1, the MPU controls temperature compensation via the
GAIN_ADJn registers (CE RAM 0x40-0x42), when 0, the CE is in
control.

21

EDGE_INT

1

When 1, XPULSE produces a pulse for each zero-crossing of
the mains phase selected by FREQSEL[1:0] , which can be used
to interrupt the MPU.

20

SAG_INT

1

When 1, activates YPULSE output when a sag condition is
detected.

19:8

SAG_CNT

252

(0xFC)

The number of consecutive voltage samples below SAG_THR
(CE RAM 0x24) before a sag alarm is declared. The default value
is equivalent to 100 ms.

7:6

FREQSEL[1:0]

0

FREQSEL[1:0] selects the phase to be used for the frequency
monitor, sag detection, and for the zero crossing counter
(MAINEDGE_X, CE RAM 0x83).

FREQ SEL[1:0]

Phase Selected

0

0

A

0

1

B*

1

X

Not allowed

*71M6542F only