Name

Location

Rst Wk Dir Description

TEMP_22[10:8]
TEMP_22[7:0]

230A[2:0]
230B[7:0]

0 –

R

Storage location for STEMP at 22C. STEMP is an 11-bit word.

TEMP_BAT

28A0[4]

0 – R/W

Causes VBAT to be measured whenever a temperature measurement is
performed.

TEMP_BSEL

28A0[7]

0 – R/W

Selects which battery is monitored by the temperature sensor: 1 = VBAT,
0 = VBAT_RTC

TBYTE_BUSY

28A0[3]

0 0

R

Indicates that hardware is still writing the 0x28A0 byte. Additional writes to
this byte will be locked out while it is one. Write duration could be as long as
6ms.

TEMP_PER[2:0]

28A0[2:0]

0 – R/W

Sets the period between temperature measurements. Automatic measurements
can be enabled in any mode (MSN, BRN, LCD, or SLP). TEMP_PER = 0
disables automatic temperature updates, in which case TEMP_START may be
used by the MPU to initiate a one-shot temperature measurement.

TEMP_PER

Time (seconds)

0

No temperature updates

1-6

2

(3+TEMP_PER)

7

Continuous updates

TEMP_PWR

28A0[6]

0 – R/W

Selects the power source for the temp sensor:
1 = V3P3D, 0 = VBAT_RTC. This bit is ignored in SLP and LCD modes,
where the temp sensor is always powered by VBAT_RTC.

TEMP_START

28B4[6]

0 0 R/W

When TEMP_PER = 0 automatic temperature measurements are disabled,
and TEMP_START may be set by the MPU to initiate a one-shot temperature
measurement. TEMP_START is ignored in SLP and LCD modes. Hardware
clears TEMP_START when the temperature measurement is complete.

TMUX[5:0]

2502[5:0]

R/W Selects one of 32 signals for TMUXOUT. See

2.5.12

for details.

TMUX2[4:0]

2503[4:0]

R/W Selects one of 32 signals for TMUX2OUT. See

2.5.12

for details.

TMUXRA[2:0]

270A[2:0]

000 000 R/W The TMUX setting for the remote isolated sensor (71M6x01).

VERSION[7:0]

2706[7:0]

– –

R

The silicon version index. This word may be read by firmware to determine
the silicon version.

VERSION[7:0] Silicon Version
0001 0011
0010 0010

B01
B02

VREF_CAL

2704[7]

0 0 R/W

Brings the ADC reference voltage out to the VREF pin. This feature is disabled
when VREF_DIS=1.

VREF_DIS

2704[6]

0 1 R/W Disables the internal ADC voltage reference.