4.3

71M6541D/F Using Local Sensors

Figure 35

shows a 71M6541D/F configuration using locally connected current sensors. The IAP-IAN

current channel may be directly connected to either a shunt resistor or a CT, while the IBP-IBN channel is
connected to a CT and is therefore isolated. This configuration implements a single-phase measurement
with tamper-detection using one current sensor to measure the neutral current. This configuration can
also be used to create a split phase meter (e.g., ANSI Form 2S). For best performance, both the IAP-IAN
and IBP-IBN current sensor inputs are configured for differential mode (i.e., DIFFA_E = 1 and DIFFB_E =
1, I/O RAM 0x210C[4] and 0x210C[5]). The IBP-IBN input must be configured as an analog differential
input disabling the remote sensor interface (i.e., RMT_E = 0, I/O RAM 0x2709[3]). See

Figure 2

for the AFE

configuration corresponding to

Figure 35

.

MPU

RTC

TIMERS

IAP

VA

IBP

XIN

XOUT

RX

TX

TX

RX

COM0...5

V3P3A V3P3SYS

VBAT

VBAT_RTC

SEG

GNDA GNDD

SEG/DIO

DIO

ICE

LINE

NEUTRAL

LOAD

8888.8888

PULSES,

DIO

IR

AMR

POWER FAULT
COMPARATOR

MODUL-

ATOR

SERIAL PORTS

OSCILLATOR/

PLL

MUX and ADC

LCD DRIVER

DIO, PULSES

COMPUTE

ENGINE

FLASH

MEMORY

RAM

32 kHz

REGULATOR

CT

POWER SUPPLY

TERIDIAN

71M6541D/F

TEMPERATURE

SENSOR

VREF

BATTERY

PWR MODE

CONTROL

WAKE-UP

NEUTRAL

I

2

C or µWire

EEPROM

IAN

IBN

RTC
BATTERY

V3P3D

BATTERY
MONITOR

SPI INTERFACE

HOST

LCD DISPLAY

Resistor Divider

CT

LINE

LINE

Note:
This system is referenced to LINE

Shunt

or

11/5/2010

Figure 35. 71M6541D/F with Local Sensors