2 recommended external components, 3 recommended operating conditions, Recommended external components – Rainbow Electronics 71M6542G User Manual

Page 139: Recommended operating conditions, Table 95: recommended external components, Table 96: recommended operating conditions

Advertising
background image

v1.1

© 2008–2011 Teridian Semiconductor Corporation

139

6.2

Recommended External Components

Table 94: Recommended External Components

Name

From

To

Function

Value

Unit

C1

V3P3A

GNDA

Bypass capacitor for 3.3 V supply

≥0.1 ±20%

µF

C2

V3P3D

GNDD

Bypass capacitor for 3.3 V output

0.1

±20%

µF

CSYS

V3P3SYS

GNDD

Bypass capacitor for V3P3SYS

≥1.0 ±30%

µF

CVDD

VDD

GNDD

Bypass capacitor for VDD

0.1

±20%

µF

CVLCD

VLCD

GNDD

Bypass capacitor for VLCD pin (when
charge pump is used)

≥0.1 ±20%

µF

XTAL

XIN

XOUT

32.768 kHz crystal – electrically similar to
ECS .327-12.5-17X, Vishay XT26T or
Suntsu

SCP6–32.768kHz TR (load

capacitance 12.5 pF).

32.768

kHz

CXS

XIN

GNDA

Load capacitor values for crystal depend on
crystal specifications and board parasitics.
Nominal values are based on 4 pF board
capacitance and include an allowance for
chip capacitance.

15

±10%

pF

CXL

XOUT

GNDA

10

±10%

pF

6.3

Recommended Operating Conditions

Unless otherwise specified, all parameters listed in

6.4 Performance Specifications

and

6.5 Timing

Specifications

are valid over the Recommended Operating Conditions provided in

Table 95

below.

Table 95: Recommended Operating Conditions

Parameter

Condition

Min

Typ

Max

Unit

V3P3SYS and V3P3A Supply Voltage for
precision metering operation (MSN mode).
Voltages at VBAT and VBAT_RTC need
not be present.

VBAT=0 V to 3.8 V
VBAT_RTC =0 V to
3.8 V

3.0

3.6

V

VBAT Voltage (BRN mode). V3P3SYS is
below the 2.8 V comparator threshold.
Either V3P3SYS or VBAT_RTC must be
high enough to power the RTC module.

V3P3SYS < 2.8 V
and
Max (VBAT_RTC,
V3P3SYS) > 2.0 V

2.5

3.8

V

VBAT_RTC Voltage. VBAT_RTC is not
needed to support the RTC and non-
volatile memory unless V3P3SYS < 2.0 V

V3P3SYS<2.0 V

2.0

3.8

V

Operating Temperature

-40

+85

ºC

Notes:

1. GNDA and GNDD must be connected together.
2. V3P3SYS and V3P3A must be connected together.

Advertising