GE Industrial Solutions AF-650 GP General Purpose Drive (460_575_690V 125HP and above) User Manual

Page 65

Advertising
background image

3.7.3 Speed Up/Down

Terminals 29/32 = Speed up/down:.

Terminal 18 = par. E-01 Terminal 18 Digital Input Start [9] (default)

Terminal 27 = par. E-03 Terminal 27 Digital Input Freeze reference
[19]

Terminal 29 = par. E-04 Terminal 29 Digital Input Speed up [21]

Terminal 32 = par. E-05 Terminal 32 Digital Input Speed down [22]

3.7.4 Potentiometer Reference

Voltage reference via a potentiometer:

Reference Source 1 = [1] Analog input 53 (default)

Terminal 53, Low Voltage = 0 Volt

Terminal 53, High Voltage = 10 Volt

Terminal 53, Low Ref./Feedback = 0 RPM

Terminal 53, High Ref./Feedback = 1500 RPM

Switch S201 = OFF (U)

AF-650 GP High Power Operating Instructions

64

3

Advertising