Af-650 gp high power operating instructions, 8 sp -## spec ial functions – GE Industrial Solutions AF-650 GP General Purpose Drive (460_575_690V 125HP and above) User Manual

Page 91

Advertising
background image

Par

. No.

#

Pa

ram

et

er d

escri

ption

De

fa

ul

t va

lu

e

4-set-u

p

Ch

an

ge

du

rin

g

ope

ra-

tion

Co

nv

er

-

sion inde

x

Typ

e

SP-1#

SP

-1

0

Li

ne f

ail

ur

e

[0] No function

All set-ups

FA

LSE

-

U

int8

SP

-1

1

Li

ne

Vol

tage

at I

np

ut

Fa

ul

t

Ex

pr

essio

nLimit

All se

t-u

ps

TR

U

E

0

Uin

t16

SP

-12

Fu

nc

tion

at L

in

e Im

bal

an

ce

[0] T

rip

All se

t-u

ps

TR

U

E

-

Ui

nt

8

SP-2#

SP

-2

3

Type

cod

e Se

tting

nu

ll

2 set-ups

FA

LSE

-

U

int8

SP

-2

4

Tr

ip

D

el

ay

at

Cu

rr

en

t Li

mi

t

60 s

All se

t-u

ps

TR

U

E

0

Ui

nt

8

SP

-25

Tri

p De

la

y a

t T

orqu

e L

imi

t

60

s

Al

l set-up

s

TRUE

0

U

int8

SP

-2

6

Tr

ip

De

la

y a

t Dri

ve Fau

lt

Ex

pr

essio

nLimit

All se

t-u

ps

TR

U

E

0

Ui

nt

8

SP

-2

8

Pr

odu

ct

ion

Se

tt

in

gs

[0

] N

o

ac

tio

n

All s

et

-u

ps

TR

U

E

-

Ui

nt

8

SP

-2

9

Se

rv

ice

Co

de

0 N

/A

All se

t-u

ps

TR

U

E

0

In

t3

2

SP-3#

SP

-3

0

Cu

rr

en

t L

im C

on

t, Prop

orti

ona

l Gain

10

0 %

All se

t-u

ps

FAL

SE

0

Uin

t16

SP

-31

Cur

rent Li

m Con

tr

, Int

egr

atio

n T

im

e

0.020

s

All set-u

ps

FA

LSE

-3

Ui

nt16

SP-4#

SP

-4

0

VT

Lev

el

66 %

All set-ups

FA

LSE

0

U

int8

SP

-4

1

En

er

gy

S

av

in

gs Mi

n. Ma

gn

eti

satio

n

Ex

pr

essio

nLimit

All se

t-u

ps

TR

U

E

0

Ui

nt

8

SP

-4

2

En

er

gy Sa

vi

ng

s Mi

n. Fr

eq

ue

nc

y

10

Hz

Al

l set-up

s

TRUE

0

U

int8

SP

-4

3

Motor C

osphi

Ex

pr

essio

nLimit

All se

t-u

ps

TR

U

E

-2

Uin

t16

SP-5#

SP

-5

0

RF

I F

ilt

er

[1] O

n

1 set-u

p

FAL

SE

-

Ui

nt

8

SP

-52

Fan

Ope

rat

ion

[0] Auto

All set-ups

TR

U

E

-

U

int8

SP

-5

3

Fa

n Mo

ni

to

r

[1] War

ning

All se

t-u

ps

TR

U

E

-

Ui

nt

8

SP

-5

5

O

ut

pu

t F

ilt

er

[0] No

Fi

lter

1 se

t-up

FA

LS

E

-

U

int8

SP

-5

6

Capac

itan

ce

O

utp

ut

Fi

lter

2.0 u

F

1 set-u

p

FAL

SE

-7

Uin

t16

SP

-5

7

Ind

uc

ta

nc

e O

utp

ut Fi

lte

r

7.000 m

H

1 set-u

p

FA

LSE

-6

U

in

t16

SP

-5

9

Actu

al

Nu

mb

er

o

f Inv

er

ter

Un

its

Ex

pr

essio

nLimit

1 set-u

p

FAL

SE

0

Ui

nt

8

SP-6#

SP

-6

3

O

pti

on

Su

ppl

ie

d by

Ext

ern

al

24V

DC

[1] Y

es

2 set-ups

FAL

SE

-

Ui

nt

8

SP-7#

SP

-7

1

Ac

ce

l T

im

e 1 S-

ra

mp

R

at

io at

Ac

ce

l. S

tart

50 %

All se

t-u

ps

TR

U

E

0

Ui

nt

8

SP

-7

2

Ac

ce

l T

im

e 1 S-

ra

mp

Rat

io at

Ac

ce

l. E

nd

50 %

All se

t-u

ps

TR

U

E

0

Ui

nt

8

SP

-7

3

De

ce

l Ti

me

1

S-r

amp

Ra

tio a

t De

ce

l. Sta

rt

50 %

All se

t-u

ps

TR

U

E

0

Ui

nt

8

SP

-7

4

D

ec

el

T

im

e 1 S

-ram

p R

at

io

at

D

ec

el

. En

d

50 %

All s

et

-u

ps

TR

U

E

0

Ui

nt

8

SP

-7

6

Ac

ce

l/De

ce

l Ti

m

e 2

Ty

pe

[0] Linear

All se

t-u

ps

TR

U

E

-

Ui

nt

8

SP

-7

9

Ac

ce

l T

im

e 2 S-

ra

mp

Rat

io at

Ac

ce

l. S

tart

50 %

All se

t-u

ps

TR

U

E

0

Ui

nt

8

SP-8#

SP

-8

0

Ac

ce

l T

im

e 2 S-

ra

mp

R

at

io at

Ac

ce

l. E

nd

50 %

Al

l set-up

s

TRUE

0

U

int8

SP

-8

1

De

ce

l Ti

me

2

S-r

amp

Ra

tio a

t De

ce

l. Sta

rt

50 %

All se

t-u

ps

TR

U

E

0

Ui

nt

8

SP

-8

2

D

ec

el

T

im

e 2 S

-ram

p R

at

io

at

D

ec

el

. En

d

50 %

All s

et

-u

ps

TR

U

E

0

Ui

nt

8

SP

-8

4

Acc

el

/D

ece

l R

amp

3

Ty

pe

[0] Linear

All se

t-u

ps

TR

U

E

-

Ui

nt

8

SP

-8

7

Ac

ce

l T

im

e 3 S-

ra

mp

Rat

io at

Ac

ce

l. S

tart

50 %

All se

t-u

ps

TR

U

E

0

Ui

nt

8

SP

-8

8

Ac

ce

l T

im

e 3 S-

ra

mp

R

at

io at

Ac

ce

l. E

nd

50 %

All se

t-u

ps

TR

U

E

0

Ui

nt

8

SP

-8

9

D

ec

el

T

im

e 3 S

-ram

p R

at

io

at

D

ec

el

. S

tart

50 %

All s

et

-u

ps

TR

U

E

0

Ui

nt

8

SP-9#

SP

-9

0

De

ce

l Ti

me

3

S-r

amp

Ra

tio a

t De

ce

l. E

nd

50 %

Al

l set-up

s

TRUE

0

U

int8

SP

-9

2

Acc

el

/D

ece

l R

amp

4

Ty

pe

[0] Linear

All se

t-u

ps

TR

U

E

-

Ui

nt

8

SP

-9

5

Ac

ce

l T

im

e 4 S-

ra

mp

Rat

io at

Ac

ce

l. S

tart

50 %

All se

t-u

ps

TR

U

E

0

Ui

nt

8

SP

-9

6

Ac

ce

l T

im

e 4 S-

ra

mp

R

at

io at

Ac

ce

l. E

nd

50 %

All se

t-u

ps

TR

U

E

0

Ui

nt

8

SP

-9

7

D

ec

el

T

im

e 4 S

-ram

p R

at

io

at

D

ec

el

. S

tart

50 %

All s

et

-u

ps

TR

U

E

0

Ui

nt

8

SP

-9

8

De

ce

l Ti

me

4

S-r

amp

Ra

tio a

t De

ce

l. E

nd

50 %

All se

t-u

ps

TR

U

E

0

Ui

nt

8

4.3.

8

SP

-## Spec

ial Functions

AF-650 GP High Power Operating Instructions

90

4