Pre-installation – ClimaCool UGW Manual User Manual

Page 4

Advertising
background image

www.climacoolcorp.com

2

Inspection

Upon receipt of equipment, carefully check the shipment

against the bill of lading and inspect each chiller for any

damage incurred during shipment . Thoroughly check for

any visible damage of control panels and electrical

and/or refrigeration components or broken copper lines .

The carrier must make proper notation of any damages or

shortages on all copies of the bill of lading and complete

a common carrier inspection report prior to your final

acceptance of the shipment . Note: It is the responsibility

of the purchaser to file all necessary claims with the

carrier. In addition, please notify the ClimaCool Customer

Service Department at 405.815.3000 or customerservice@

climacoolcorp.com of all damage immediately.

Storage

Chillers should be stored in an upright position and kept in a

clean, dry area .

Handling of Modules

Carefully remove the module’s packaging . The chiller’s

steel base cutouts provide maneuverability by forklift or

pallet jack into its final position (See Rigging and Lifting

Procedures on page 7) . Verify that all header grooved

couplings and mounting hardware kits are on site prior to

connecting the modules . Note: Consult factory for handling

other than in the upright position.

Rigging and Lifting

Each module should be lifted using a pallet jack or fork

lift . If it is necessary to utilize a crane for rigging or lifting,

each module shall be lifted using lifting straps and spreader

bars using rigging points identified on Rigging and Lifting

Procedures on page 7 .

Warranty

To ensure proper equipment longevity, design performance

and reliability, all ClimaCool chillers must be installed,

operated and maintained in accordance with ClimaCool

IO&M manuals . Water quality is of the utmost importance

for the proper care and maintenance of your modular

chiller system . Regular treatment of the water will increase

longevity of your system . Failure to provide adequate

filtration or treatment of evaporator and condenser

water will void the ClimaCool module’s warranty. A

factory authorized technician is required to perform

the startup of your ClimaCool chiller . Please contact the

ClimaCool Customer Service Department at 405-815-3000

or

technicalsupport@climacoolcorp .com to schedule . There is

a minimum of three (3) weeks’ notice required to schedule

your factory startup.

Pre-Installation

Advertising