Stainless steel strainer option – ClimaCool UGW Manual User Manual

Page 55

Advertising
background image

53

www.climacoolcorp.com

Stainless Steel Strainer Option

Figure 20 - Stainless Steel Strainer

Safety Considerations

Prior to installation, this manual must be read carefully

and all instruction understood . Personal injury or product

damage can occur if the following safety precautions are

overlooked or ignored . It is strongly recommended to follow

these safety precautions and avoid the potential hazards

listed below when operating and maintaining

your strainer:
1. After unpacking your strainer, carefully inspect your

strainer housing, lid assembly and screen for damaged

or missing parts . Contact ClimaCool’s customer service

department for any replacement parts .

2. The strainer should not be modified or used in a

manner not consistent with the manufacture’s

recommendations . If there are any questions regarding

its application or installations, contact ClimaCool’s

customer service department .

3. Absolutely under no conditions should the strainer

id or pressure gauges be removed while the strainer

is pressurized.

4. Standard bolted lid models should never exceed 150 psi;

V-Band clamp models should never exceed 125 psi .

5. Install back-flow prevention devices (or check valves)

both upstream and downstream of the strainer to

prevent back flow or vacuum effects which can cause

damage to the strainer housing or screen .

6. Install properly sized pressure relief valves both

upstream and downstream of the strainer . This will

help prevent damage to the strainer and screen in the

event that water flow is stopped abruptly, or if water

hammering occurs . The pressure relief valves should

be set to relieve pressure at 1 .2 times the strainer’s

maximum operating pressure (not to exceed the

maximum rated pressure) . Consult your local dealer or

pressure relief valve manufacturer to obtain properly

sized valves for your application .

Note: Minimum 60 mesh screen is required. At no time

should the internal pressure exceed the maximum rated

pressure of the strainer.

Strainer Installation Recommendations

The following the guidelines are recommended when

installing the strainer:
1. The CS strainer should be placed on a firm, supporting

surface . Failure to do so can cause stress on the weld

joints . It is recommended a concrete pad be poured

under the base of the strainer . The weight of the CS

strainer should not be supported by the main water

lines connecting it .

2. The inlet and outlet connections should be securely

fastened. The arrows depict flow direction (see

Figure 20) .

3. The back-mount pressure gauges should be installed

in the gauge ports located on the front of the strainer

body . These gauges will allow you to monitor the

pressure differential across the strainer screen providing

an indication when the strainer element is clogged and

requires cleaning .

4. The CS strainer lid must be securely fastened according

to the following torque specifications to ensure product

safety and an adequate seal .

Torque Specifications

Clamped Lid Models: CS strainer models 3CS and 4CS have

“over-center latch clamp” lid designs . The over-center

clamp does not require adjustment when installing or

removing the lid . The lock washer is set at the factory for

proper clamp compression and normally requires no field

adjustment . Minor tightening may be necessary over time .

The lids are installed as follows:
1. Place the clamp around the strainer lid .

2. Latch the T-bolt with the receiver and push the latch

handle towards the strainer body until the safety

catch engages .

Bolted Lid Models: CS strainer models 6CS, 8CS and 10CS

have “bolted” lid designs . Grade 5 zinc-plated bolts, nuts

and washers are used to attach the lids to these strainers .

See Table 2 for proper lid bolt size and torque rating for each

strainer (page 54). (Exercise care when tightening the lid

bolts so as not to damage the strainer lid or housing) .
It is important to follow the torque specifications as

over-tightening may result in premature failure of the bolts .

It is equally important to follow a star wheel torque pattern

when tightening the lid bolts (see Figure 21). The strainer lid

may not be seated down completely after the first torque

sequence . A second torque sequence should be adequate to

seat the lid securely to the body .

Advertising