Shell and Tube Condenser

Factory installed cleanable shell and tube condenser with

enhanced copper tube geometry . Provides removable,

epoxy coated, water plates to facilitate cleaning . Contact
factory for application parameters .

Motorized or Manual Water Isolation Valves

and Flush Ports

Factory installed water isolation valves and flush ports
provide isolation to the module for maintenance and
cleaning of evaporator and condenser heat exchangers
while adjacent modules continue normal operation . Both
motorized and manual valves include standard ¾” fill and
flush valves.
Motorized condenser water valves provide head pressure
regulation for low entering condenser water temperature
applications (less than 60°F).
Available choices include:

• (1) each motorized valve for evaporator and condenser

with (1) each manual valves for the evaporator and
condenser .

• (1) each motorized valve for the evaporator and (1) each

manual valve for the evaporator and (2) each manual
valves for the condenser .

• (2) each manual valves for the evaporator and

the condenser .

Hot Gas Bypass

For normal leaving chilled water temperature setpoint of

44

0

F, verify that the cut-in pressure is set at 31 .5 psig . For

water and glycol systems operating at lower leaving design

temperatures, cut-in pressure must be field adjusted at

approximately 4 psig above the equivalent water/glycol
temperature solution freeze point .

Pressure Differential Flow Sensor/Switch

Field installed to prevent operation of chiller without
sufficient water flow to evaporator and condenser.

Manual Strainers

Field installed strainers are external to the chiller bank to
increase efficiency and ensure long life of the modules.
A minimum 60 mesh stainless steel screen is required to
protect both the condenser and evaporator circuit .

Automatic CS Series Strainer Package

Field installed high quality stainless steel filtration systems

with minimum 60 mesh stainless steel screens . Available

options include pressure differential alarm and automatic

time flush.

Water Header Bypass

Factory installed to prevent deadheading the pump, a water
header bypass may be utilized and is mandatory when using
motorized valves .
Options available for following:
• Direct Return:

• Motorized evaporator/condenser water

isolation valves

• Motorized evaporator/manual condenser water

isolation valves

• Reverse Return:

• Motorized evaporator/condenser water

isolation valves

• Motorized evaporator/manual condenser water

isolation valves