IAI America PCON-CFA User Manual

Page 103

Advertising
background image

4. SCON-CA


97

Setting of parameter No. 25

512-point mode

Solenoid valve mode 1

Solenoid valve mode 2

3 4 5

Category Port No.

Symbol

Signal name

Symbol

Signal name

Symbol

Signal name

0 PC1

ST0 Start

position

0

ST0 Start

position

0

1 PC2

ST1 Start

position

1

ST1 Start

position

1

2 PC4

ST2 Start

position

2

ST2 Start

position

2

3 PC8

ST3 Start

position

3

-

4 PC16

ST4 Start

position

4

-

5 PC32

ST5 Start

position

5

-

6 PC64

ST6 Start

position

6

-

7 PC128

-

-

8 PC256

Command position

number

-

Cannot be used.

-

Cannot be used.

9

BKRL

Forced brake release

BKRL

Forced brake release

BKRL

Forced brake release

10 RMOD Operation

mode RMOD

Operation mode

RMOD

Operation mode

11

HOME

Home return

HOME

Home return

-

12 *STP

Pause

*STP

Pause

-

13

CSTR

Positioning start

-

Cannot be used.

-

Cannot be used.

14 RES

Reset

RES

Reset

RES

Reset

PLC

output

o

PCON

-CA/CFA

input

15

SON

Servo ON command

SON

Servo ON command

SON

Servo ON command

0

PM1

PE0

Completed position 0

LS0

Rear end move

command 0

1

PM2

PE1

Completed position 1

LS1

Rear end move

command 1

2

PM4

PE2

Completed position 2

LS2

Rear end move

command 2

3

PM8

PE3

Completed position 3

-

4

PM16

PE4

Completed position 4

-

5

PM32

PE5

Completed position 5

-

6

PM64

PE6

Completed position 6

-

Cannot be used.

7

PM128

ZONE1

Zone 1

ZONE1

Zone 1

8 PM256

Completed position

number

PZONE/

ZONE2

Position zone/

Zone2

PZONE/

ZONE2

Position zone/

Zone2

9

RMDS

Operation mode

RMDS

Operation mode

RMDS

Operation mode

10 HEND

Home return

complete

HEND

Home return complete

HEND

Home return complete

11 PEND

Positioning

complete

PEND

Positioning complete

-

Cannot be used.

12

SV

Operation ready

SV

Operation ready

SV

Operation ready

13 *EMGS Emergency

stop *EMGS

Emergency stop

*EMGS

Emergency stop

14 *ALM

Alarm

*ALM

Alarm

*ALM

Alarm

PCON

-CA/CFA
output

o

PLC

input

15

LOAD/

TRQS/

*ALML

Load output

judgment/

torque level/

Light error status

LOAD/
TRQS/
*ALML

Load output judgment/

torque level/

Light error status

*ALML

Light error status

* indicates a signal that is normally ON.
The signals denoted by “Cannot be used” are not controlled. (ON/OFF statuses of these signals are
indeterminable.)