Acon – IAI America PCON-CFA User Manual

Page 30

Advertising
background image

3. SCON-CA/CF

A


24

ACON

Setting of parameter No. 25

512-point mode

Solenoid valve mode 1

Solenoid valve mode 2

3 4 5

Category Port No.

Symbol

Signal name

Symbol

Signal name

Symbol

Signal name

0 PC1

ST0 Start

position

0

ST0 Start

position

0

1 PC2

ST1 Start

position

1

ST1 Start

position

1

2 PC4

ST2 Start

position

2

ST2 Start

position

2

3 PC8

ST3 Start

position

3

-

4 PC16

ST4 Start

position

4

-

5 PC32

ST5 Start

position

5

-

6 PC64

ST6 Start

position

6

-

7 PC128

-

-

8 PC256

Command position

number

-

Cannot be used.

-

Cannot be used.

9

BKRL

Forced brake release

BKRL

Forced brake release

BKRL

Forced brake release

10 RMOD Operation

mode RMOD

Operation mode

RMOD

Operation mode

11

HOME

Home return

HOME

Home return

-

12 *STP

Pause

*STP

Pause

-

13

CSTR

Positioning start

-

Cannot be used.

-

Cannot be used.

14 RES

Reset

RES

Reset

RES

Reset

PLC

output

o

ACON

input

15

SON

Servo ON command

SON

Servo ON command

SON

Servo ON command

0

PM1

PE0

Completed position 0

LS0

Rear end move

command 0

1

PM2

PE1

Completed position 1

LS1

Rear end move

command 1

2

PM4

PE2

Completed position 2

LS2

Rear end move

command 2

3

PM8

PE3

Completed position 3

-

4

PM16

PE4

Completed position 4

-

5

PM32

PE5

Completed position 5

-

6

PM64

PE6

Completed position 6

-

Cannot be used.

7

PM128

ZONE1

Zone 1

ZONE1

Zone 1

8 PM256

Completed position

number

PZONE

Position zone

PZONE

Position zone

9

RMDS

Operation mode

RMDS

Operation mode

RMDS

Operation mode

10 HEND

Home return

complete

HEND

Home return complete

HEND

Home return complete

11 PEND

Positioning complete

signal

PEND

Positioning complete

signal

-

Cannot be used.

12

SV

Operation ready

SV

Operation ready

SV

Operation ready

13 *EMGS Emergency

stop *EMGS

Emergency stop

*EMGS

Emergency stop

14 *ALM

Alarm

*ALM

Alarm

*ALM

Alarm

ACON

output

o

PLC

input

15

-

Cannot be used.

-

Cannot be used.

-

Cannot be used.

* indicates a signal that is normally ON.
The signals denoted by “Cannot be used” are not controlled. (ON/OFF statuses of these signals are
indeterminable.)